Topic: DMD0450 Module Configuration for GS-EDRV100s |
|
When a Do-more's Ethernet I/O Master is configured to use a GS-EDRV100 it will automatically create a new module configuration. Clicking the Edit Config button in the Module Configuration utility will open the following dialog where the default configuration can be changed.
The Module Configuration's Name will become a Device, which be used in instructions that target this GS Drive. Be careful to choose a meaningful and unique name; module configuration names follow Nickname RulesNicknames can be 1 to 16 characters in length and consist of any combination of alphanumeric characters and underscores ('_', 'a-z', 'A-Z', 0-9), no spaces or punctuation marks are allowed, and must begin with a letter or an underscore..
Do-more PLCs use the Ethernet I/O Master to communicate over the local Ethernet Port through a GS-EDRV100, which is connected serially to the GS1, GS2, GS3 DURAPulse, or GS4 DURAPulse A/C Motor Drive. See the Help topic for the System Structures for details on the member fields of a GS Drive structure.
|
|